Description
DESCRIPTION
The His-Spin Protein Miniprep provides a fast spin-column based purification technology for His-tagged proteins. Up to 1 mg of His-tagged protein can be purified in 5 minutes and eluted in as little as 100 µl of His-Elution Buffer. The purified protein is ultra-pure and can be used directly for enzymatic assays, protein biochemical analyses, SDS-PAGE and other sensitive applications. The straightforward spin, wash, and elute protocol dramatically simplifies protein purification and allows the end user to get results in minutes, not hours.
Affinity Matrix |
Nickel charged agarose |
Binding Capacity |
1 mg |
Elution Method |
Imidazole gradient |
Elution Volume |
100 – 200 µl (150 µl is optimal) |
Principle of Technology |
Based on a nickel-charged His-Affinity Gel (IMAC). |
Processing Time |
5 minutes |
Product Storage |
Please store the His-Affinity Gel, His-Binding Buffer, His-Wash Buffer, and His-Elution Buffer at 4°C. The other components can be stored at room temperature. |
Protein Purity |
Electrophoretically pure. Purified high-quality protein is suitable for enzyme kinetics, protein biochemical analyses, SDS-PAGE, and other applications. |
Required Equipment |
Microcentrifuge |
Sample Type |
Cell lysates or other complex protein mixtures containing His-tagged proteins. |